2026-04-10Views:
1. Check the joint contact and insulation resistance of the electrical part of the air compressor
you can first use an ammeter to detect the current value of each item or use an infrared temperature measuring gun to detect the temperature of the incoming terminal, and make a preliminary judgment to assist in judging whether the wire head is loose.
2. Maintenance of oil filling motor
bearing in the proper lubrication to ensure life, the front and rear end of the motor is equipped with bearings. Normal operation, so grease should be injected regularly, and the type of grease should be selected according to the parameters provided by each manufacturer.
3. Clean the intake valve and filter element
1) Removal of the relief valve: Remove the hose connecting the relief valve and the air filter (note that debris must not enter the air inlet);
2) Remove all other air pipes connected with the relief valve;
3) Remove the solenoid valve coil;
4) Remove the nut assembled between the relief valve and the host and take it down;
5) Move the relief valve to the ground covered with clean paper or related clean laying.
The cleaning method of the air intake filter element is to take out the filter element and gently tap its upper and lower end surfaces, or gently blow off with compressed air to clean the dust and dirt on the filter element. Do not scrub with oil or water. If the filter paper is found to be damaged or heavily clogged with dust and dirt, it must be replaced with a new one.
4, cleaning small pressure valve (also known as pressure maintenance valve)
1) cleaning small pressure valve: according to the method of cleaning relief valve cleaning small pressure valve.
2) Assembly of small pressure valve: The structure of small pressure valve is very simple. It can take out all the internal components by disassembling the valve body cover.
3) Assembly of small pressure valve: Assemble components according to the reverse steps of disassembly. The assembly process will not be described one by one, but attention should be paid to the direction of the U-ring when there is a U-ring inside.
5. Clean the return check valve
1) assembly of return check valve: the valve body has a connection. Take out the spring, steel ball and steel ball seat. There is also a filter screen inside the local one-way valve.
2) Clean the oil return check valve: clean the valve body, spring, steel ball and steel ball seat with cleaning agent. If any, clean them together.
3) Assembly of return check valve: Install the check valve according to the reverse steps of removal.
6. Clean the temperature control valve
cleaning temperature control valve: according to the method of cleaning relief valve cleaning temperature control valve all parts.
7. Clean the cooler
when the oil cooler fouling is more serious, you can remove the oil cooler alone, open the two end covers, with a special cleaning steel brush or other tools to remove the scale.
Knowledge of air compressor post-processing dryer: ① What is adsorption? How does adsorption occur? Adsorption is the phenomenon that the concentration of substances changes automatically at the interface of two phases. All solids have varying degrees of the ability to adsorb molecules, atoms, or ions of the surrounding medium to their own surfaces.
We can be selected for purchasing water-lubricated air compressors, oil-free and water-lubricated air compressors, integrated air compressors and frequency conversion air compressors. Contact Xiao Shen of Shanghai granklin group, and I will match you with screw air compressors suitable for your needs.
What are the common shortcomings of the screw air compressor?(1) When the screw air compressor is shut down, the air inlet is sprayed outward. When the air compressor suddenly stops and does not open the exhaust valve in time to discharge exhaust gas, the air inlet sprays cooling oil outward. At this time, first check whether the intake valve has defects and cannot be closed normally. Second, check whether the oil cut-off solenoid valve has defects. Assuming it is normal, further check whether the check valve on the main exhaust pipe can be closed in time or completely. If there are defects, it should be removed.
The use of any machine is to the correct maintenance, in order to make the machine life long. Permanent magnet variable frequency screw air compressor is no exception, the correct maintenance of permanent magnet variable frequency screw air compressor service life and maintenance costs have a great impact, this point from the actual interests of the enterprise is very necessary.
View details1. Check whether the fuse is burned and blown, causing the circuit to fail and cannot be powered on. 2. Motor failure. The insulation layer is aged or the temperature is too high, the insulation layer is melted, so that the insulation effect is insufficient and leakage occurs. 3. The motor is locked and overcurrent. Not enough lubricant,
If the maintenance of the air compressor is not timely, it will have a great impact on the air compressor. The screw air compressor will have a first guarantee for 500 hours of operation and a maintenance for 2000 hours after operation. Screw air compressor oil is good or bad on the oil injection screw
The water-lubricated air compressor uses water to lubricate the head of the air compressor. The whole machine is made of stainless steel, and the compressed gas does not contain oil. Shanghai Granklin Group, the production of [water lubricated air compressor] in the summer is as low as possible to run [oil-free air compressor]];
Compressed air is widely used and is the second largest power energy after electricity. Therefore, air compressors, as general equipment, are widely used in various industries. Air occupies a certain space, but it has no fixed shape and volume. In the right
In the past water plant construction, we generally choose the piston screw air compressor. Piston screw air compressor has the advantages of low investment cost and large compression ratio, but at the same time, screw air compressor also has many moving parts, easy to wear and tear, and large maintenance workload. In the past water plant construction, we generally choose the piston screw air compressor. Piston screw air compressor has the advantages of low investment cost and large compression ratio, but at the same time, piston air compressor also has many moving parts, easy to wear, maintenance and repair workload is large and so on.
View detailsFrom the oil content point of view, the oil and no oil in the air compressor generally refers to the amount of oil in the exhaust outlet of the air compressor. There is also a completely oil-free air compressor, which is not Oil lubrication is used, but water lubrication is used, so the final discharge of gas without oil is called water lubricated air compressor.
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2