2026-04-10Views:
What are the safety measures in the work of the air compressor?
(1) When the compressed air is cooled, the oil-water mixture condensed in the cooler, air storage barrel and oil separator must be blown off in time, at least once per hour.
(2) When the air compressor is working, if the cooling water supply is not timely, it must be parked immediately to be cooled.
(3) Before the air compressor is started, the water jacket of the cylinder and the cooler is advanced with water.
(4) Before the cylinder water jacket is completely cooled, no water is allowed to enter to prevent cracks in the cylinder wall.
(5) The cooling water entering the water jacket shall be put into a special water tank with water pressure drop. The water tank shall be equipped with a horizontal level indicator scale. When the horizontal level falls below the limit, the signal equipment will take effect. Centrifugal pump can also be selected to feed water; Do not directly use the self-leiyuan water pipe to feed water, because it is difficult to see whether water enters or not.
(6) Drainage from the cylinder water jacket or cooler water jacket must be made with an open liquid flow in order to view the uninterrupted effect of all cooling equipment and measure the drainage temperature. The drainage temperature shall not be 20 ℃-30 ℃ higher than the inlet water temperature.
(7) In order to prevent blasting caused by overpressure, the compressor shall be equipped with a pressure gauge and safety valve that have passed the verification.
(8) When compressed air must be introduced into a system with lower pressure, a pressure reducer must be provided.
(9) In order to prevent the compressor system from breaking due to the ignition of the gas explosive mixture, the following measures must be taken:
(10) When checking and repairing, special attention must be paid to prevent scrubbing materials, wood blocks, etc. from falling into cylinders, air storage barrels and pipes, because such substances may catch fire in compressed air.
(11) When cleaning the cylinder wall, use kerosene, not gasoline, and scrub cloth not too much oil.
(12) After cleaning, the cylinder head must be opened to allow the fuel to evaporate completely.
(13) When using compressed air, the airflow direction must not be toward the staff.
(14) the oil inside the air compressor connecting pipe must be carefully cleaned; according to the operation of the equipment, the cleaning cycle is generally 3 to 6 months.
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2