Screw air compressor how to maintain

2026-04-10Views:

The normal operation of the factory is inseparable from the stability of the equipment, and the stability of the equipment is not only related to its performance, but also inseparable from the daily cleaning and maintenance. The correct maintenance steps can not only keep the equipment in good performance, but also improve the product yield, but also save part of the maintenance cost for the enterprise. The following is an inventory of common maintenance methods for screw air compressors of important gas equipment in enterprises.

air compressor maintenance and maintenance:

regular maintenance of important parts of the 1.

In order to ensure the service life of the unit, it is necessary to formulate a detailed maintenance plan, perform fixed-person operation, regular maintenance, and regular inspection and maintenance to keep the air compressor unit clean, oil-free, and dirt-free.

2. clean cooler:

the screw air compressor needs to clean the cooler every 2000h or so. Open the blowing hole cover of the cooler on the fan bracket, and blow the cooler with the dust blowing gun, guiding the dust on the surface of the cooler to be cleaned.

3. lubricating oil replenishment

there is a requirement for the amount of lubricating oil during the operation of the unit. The oil level should be kept between the low z and the high z oil level. Too little will affect the lubrication and cooling of the unit. Therefore, it should be replenished in time when the amount of oil is found to be low. Too much will lead to an increase in the oil content of the compressed air and also increase the processing capacity of the filter device.

4. drain condensate

we all know that the air contains moisture, the air compressor will contain moisture in the air suction unit, the unit will form a large number of low temperature operation of condensed water, if this part of the condensed water can not be discharged in time will affect the lubrication of components and will also rust the parts. Especially in humid climates, when the exhaust temperature is lower than the air pressure dew point or shutdown cooling, condensation water is much more than usual. This requires us to master its emission time.

Screw air compressor maintenance should be carried out in strict accordance with the provisions, pay attention to daily inspection, maintenance, wearing parts replacement is an important prerequisite to maintain the good operation of the unit.