Maintenance and maintenance of air compressor

2026-04-10Views:

there are many kinds of air compressor maintenance contents, the contents are as follows:

1. After the evaluation and problem feedback made by professionals on the operation of the machine, check and deal with it in time.

2, check the air compressor system for water leakage, air leakage, oil leakage and other phenomena, regular shutdown maintenance.

3. Check whether the drainage of the automatic drainer of the air compressor is normal, observe the condition of the discharged water, whether it is abnormal, and deal with it in time if there is any abnormality.

4. Check whether the environment where the air compressor is located is sufficiently ventilated and the heat dissipation is sufficient.

5. Check and record the exhaust temperature and pressure. If necessary, adjust the pressure switch and ask professionals to repair it in time.

6. Clean the radiator regularly.

7, check the material consumption, timely replacement or addition.

8. Regularly check the oil level of the air compressor and the quality of the oil, and replace it in time.

More Recommendations

  • 2026-04-10

    Linyi air compressor manufacturer screw machine quotation

    Linyi Air Compressor Factory Screw Machine Quotation? Linyi, a prefecture-level city in Shandong Province, is located in the southeast of Shandong Province, the west bank of the Yellow Sea, the junction of the Yangtze River Delta Economic Circle and the Bohai Rim Economic Circle, the national key development area of the East Longhai Sea and the port industrial belt in southern Shandong Province. Granklin air compressor brand combines the "power" of air compressor with the "application" of pneumatic tools to achieve a complete screw air compressor with integrated power and application, which has won the support of our customers.

    View details
  • 2026-04-10

    Causes of high temperature during the use of screw air compressor

    Generally speaking, in the design of the air compressor, there is a design scheme of operating environment temperature (30-40 degrees). When the marine air compressor manufacturer operates at the operating ambient temperature of the design scheme, the high temperature is basically close to the maintenance temperature of the air compressor. If the ambient temperature of the air compressor is higher than the operating ambient temperature of the design scheme, the temperature of the screw air compressor will rise, causing the equipment to stop at high temperature.

    View details
  • 2026-04-10

    Main maintenance methods of screw air compressor

    The main maintenance method of screw air compressor is to replace the three filters and one oil. The main methods are: 1. Air filter element. It needs to be replaced after 1500 hours of work; 2. Lubricating oil filter element. Daily use about 2000 hours need to be replaced; 3, oil and gas

    View details
  • 2026-04-10

    Oil-free screw air compressor cold weather can not start the solution

    A large area of the country has cooled down. At too low a temperature, everyone is sitting on the work station, drinking tea or watching the latest news. The severe cold weather has brought inconvenience to the broad masses of the people, and the cycle of spring, summer, autumn and winter has been repeated. The oil-free air compressor has also reached the failure frequency.

    View details
  • 2026-04-10

    Micro-oil air compressor and oil-free air compressor which is better

    From environmental protection and maintenance, of course, it is oil-free air compressor. Oil-free air compressor is a technical improvement of oil-free air compressor. The main difference between oil-free air compressor and oil-free air compressor is the oil content of the gas discharged from the exhaust port. Oil-free air compressor

    View details
  • 2026-04-10

    How often does the air compressor oil change?

    The replacement cycle of air compressor oil is divided into three situations: 1. Mineral oil is replaced every 3 to 4 months; 2. Semi-synthetic oil is replaced every 6 to 8 months; 3. Fully synthetic oil is replaced every 10 to 11 months. The air compressor shall have the following conditions

    View details
  • 2026-04-10

    Key Points of Selection Knowledge of Oil-free Air Compressor

    Choose air compressor according to the needs of different industries and working conditions, there are corresponding standards. Then how to choose a suitable oil-free air compressor? 1. First figure out what is an oil-free air compressor and why should it be used? The oil-free air compressor has been running

    View details
  • 2026-04-10

    What are the safety measures of air compressor

    Air compressor safety management measures 1, air compressor must have a pressure gauge and safety valve. The pressure gauge must be calibrated regularly. The safety valve and pressure regulator must act reliably, and the operating pressure of the safety valve shall not exceed 1.1 times of the rated pressure. Use of oil

    View details
  • 2026-04-10

    Why does the air compressor need to discharge water regularly and what are the consequences?

    The air compressor produced by Granklin Group is water-lubricated, and the water content in the compressed gas will be relatively high, so how can the gas be treated to be free of water? At the rear end of the water-lubricated air compressor, we need to configure a gas tank to store the compressed gas. The air storage tank can be drained by an automatic drain, and there is a frozen type of drying at the rear.

    View details
  • 2026-04-10

    Common Faults and Cause Analysis of Air Compressor

    As a kind of driving power energy, the application scenario of air compressor is more common and plays a very important role in all production and processing. However, in the operation of the air compressor, the actual effect of refrigeration and heat transfer is not very good, the working pressure is abnormal, and the displacement is not enough.

    View details