Many people think that the maintenance is only the maintenance of 3 filters and 1 oil for 2000 hours. However, this is only the most basic maintenance. In-depth maintenance is divided into 5 stages, if you can do in-depth maintenance. Then the service life of your air compressor can be more long-term.
1. Run for 500 hours
1) The oil filter element is changed for the first time after the new machine is used.
2) Remove and clean the air filter element, and blow it out with low pressure compressed air below 0.2Mpa.
3) Replace the lubricating oil.
2.1000 hours of operation
1) Check the intake valve action, railings and movable parts, and add grease.
2) Clean the air filter.
3) Check the oil filter element or replace it.
3.2000 hours or 6 months of operation: whichever comes first
1) Check all pipelines.
2) Replace the lubricating oil and clean the grease.
3) Check the oil goggles and remove them for cleaning.
4, run 3000 hours or one year
1) Clean the inlet valve and vent valve.
2) Check the three-way solenoid valve.
3) Check whether the oil and gas separator is blocked
4) Check the pressure maintenance valve
5) Clean the cooler and replace the O-ring
6) Replace the air filter element and oil filter element
7) Fill the motor with lubricating grease
8) Check the action of the starter
9) Check whether the protection differential pressure switches operate normally
every 20000 hours or 4 years
1) Replace the collective bearing and oil seal, and adjust the clearance.
2) Measurement of motor insulation, should be more than 1MΩ
The general water content in the atmosphere is not a fixed value, but will be affected by temperature, humidity, geographical location and climatic conditions and other factors. In the air at normal temperature and pressure, the moisture content may be several hundred to several thousand ppm(parts per mi
Explosion-proof air compressors are mainly used in environments where explosive gases may be generated, such as in coal mines, petrochemicals, dust and explosive places. These places due to the presence of flammable gases, steam, dust, etc., once the spark or high temperature, it may cause an explosion.
As an important industrial equipment, the safe operation of air compressor is very important to ensure the smooth progress of the production process. In order to ensure the safety of the air compressor, it is necessary to take a series of safety measures. Description of safety measures: 1. Equipment design
What are the application scenarios of air compressor? Air compressor is the core equipment of pneumatic system, it is the device that converts mechanical energy into gas pressure, and it is the pressure generating device of compressed air. The scope of application is mainly: general air compressor use industry: 1
The large maintenance cycle of the air compressor usually depends on a number of factors, including the use of the environment, the frequency of use and the specific condition of the equipment. In general, the major maintenance of air compressors in continuous operation for 8000 to 10000 hours is a more common practice. However, this
The pressure of the air compressor pipe depends mainly on the working pressure of the air compressor, that is, the pressure of the air compressor outlet. Generally, the pressure of 3~5KG is called low pressure, 7~13KG is called medium pressure, and more than 13KG is called high pressure. In addition, in the selection of air compressor piping
There is no universal figure for the air supply pressure in the factory. 6 to 10bar is the most common range, but it is ultimately determined according to the actual running equipment in the workshop, the length of the pipeline and the fluctuation rhythm of the air consumption. If the pressure is set correctly, the equipment will run steadily and the energy consumption will not be wasted on the excess pressure drop.
The installation position of the cold dryer (freeze dryer) in the compressed air system should be comprehensively considered in combination with the process requirements, equipment characteristics and system efficiency. The following is an authoritative analysis based on technical principles and practical experience: 1. Typical Configuration Scheme Comparison Configuration Scheme
The time that the air compressor can run continuously depends on many factors, including the type of air compressor, the working environment, the load situation and maintenance. In general, the screw air compressor is designed to operate continuously for 24 hours. This air compressor in the air pressure
The oil content standard of compressed air in factory equipment usually varies according to different industries and application fields. The following are some common compressed air oil content standards and their explanations: 1. general standards Generally speaking, the oil content standard in compressed air is 5 mg/m & su
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2