Compressed air quality standards for medical enterprises cover cleanliness, oil content, microorganisms, stability, temperature and humidity, among which oil-free water lubricated air compressors have become the preferred equipment to meet the high standards of the medical industry because they can provide more pure compressed air. Specific instructions are as follows:
cleanliness compressed air for medical use must be highly pure, especially in operating rooms, intensive care units and other places that require extremely high air cleanliness. Contaminants such as bacteria, fumes, moisture and odors in the air must be effectively filtered to prevent the health of patients. Oil-free water lubrication air compressor through water lubrication technology to replace the traditional lubricating oil, from the source to eliminate the risk of oil pollution, to ensure the purity of compressed air.
Oil content: The oil content of compressed air for medical use should be strictly controlled, usually less than 0.1 mg/m & sup3;, to avoid the impact of oil on the health of patients. Oil-free water-lubricated air compressors do not need to use lubricating oil, so they can easily meet this requirement and provide oil-free compressed air.
Microbial contamination: Medical compressed air must not contain any microorganisms that are not conducive to the health of patients, such as bacteria and actinomycetes. The oil-free water lubrication air compressor can further reduce the microbial content in the compressed air through the high-efficiency filtration system, and ensure that the air quality meets the medical standards.
Stability: The flow and pressure of compressed air for medical use must be stable and there must be no sudden changes. This is especially important during surgery, as the stability of oxygen flow and concentration is critical to the patient. The oil-free water lubrication air compressor can accurately adjust the output pressure and flow through the intelligent control system to ensure the stability of the gas supply.
Temperature and humidity: The temperature and humidity of compressed air for medical use should be kept within an appropriate range to ensure that patients will not feel uncomfortable or face danger due to too high or too low temperature. At the same time, the appropriate humidity also helps to maintain the health of patients. The oil-free water lubrication air compressor can adjust the temperature and humidity of the compressed air through the supporting drying and filtering equipment to meet the medical needs.
Application Advantages of Oil-free Water Lubrication Air Compressor in Medical Enterprises:
The moisture content in the air is not a fixed value, but is affected by many factors, including temperature, humidity, geographical location and climatic conditions. In the air at normal temperature and pressure, the moisture content may be in the range of hundreds to thousands of ppm(parts per million
Wafers have strict requirements for compressed air, because any tiny oil, moisture or solid particles can have a significant impact on the wafer production process, reduce product quality, and even cause equipment damage. The following are some of the main fabs for compressed air
The oil position of the screw air compressor is usually located in the oil circuit system of the compressor and is an important part of the screw air compressor. Specifically, the oil circuit system of the screw air compressor includes the oil tank, oil filter, oil separator, oil cooler, oil pipe and other parts.
The problem of excessive moisture in the air compressor can be dealt with in the following ways: Cooler treatment: A cooler is a device that removes the moisture in the air by condensation. The cooler of the air compressor can be replaced or maintained regularly to ensure its efficient work and reduction.
The air compressor and the cold dryer have their own characteristics in the working principle, they each undertake different tasks, and together constitute an important part of the compressed air processing system. Air compressor, as the main equipment for compressed air, its working principle is mainly based on compression technology. It passes
Scroll compressors and screw compressors are different in structure and working principle, so their application scenarios are also different. Scroll compressors are widely used in various industries. In the field of air compression, it is often used to compress the air in the atmosphere.
In the chemical water treatment system of power plant, the quality requirements of compressed air mainly focus on cleanliness, dryness, oil content, etc. The specific requirements are as follows: cleanliness requires dust particle size: dust particle size in purified gas should not be greater than 1μm to ensure compressed air
When the oil content of the compressed air needs to reach a very low level of ≤ 0.01ppm, it is usually recommended to use an oil-free air compressor. The oil-free air compressor does not use lubricating oil during the compression process, so it can ensure that the compressed air produced is almost completely oil-free, which is very suitable for air
The oil-free air compressor realizes lubrication through the following two core ways to ensure the efficient operation of the equipment and the pure and oil-free output air: 1. The technical principle of self-lubricating material: The key moving parts (e. g. piston rings, cylinder walls) are made of special materials that rub against each other.
The air source pressure at the chemical site varies according to specific application scenarios and process requirements. The common pressure range covers low to medium pressure, specifically including instrument air pressure (0.4-0.7MPa), common industrial compressed air pressure (0.6-1.0MPa), and chemical steam pressure level (low pressure ≤