Granklin Air Compressor Advertising Copy - Welcome to Join and Order

How to connect two air compressors

2026-04-15Views:

The connection mode of two air compressors is mainly parallel and tandem two, depending on your gas needs, site conditions and equipment characteristics. The following is a detailed description of the two connection methods and operating instructions:

1. parallel connection (recommended for increased gas supply)

applicable Scenarios: Large flow demand, stable gas supply pressure, or as standby equipment.

1. Electrical wiring steps

  • main circuit connection:
    • connect the three-phase four-wire power lines of each air compressor to their respective control boxes to ensure reliable grounding of the ground wire.
    • The three-core wire of the motor is connected to the lower end terminal of the contactor, and the phase sequence is consistent (if the motor is reversed, replace any two-phase live wire).
  • Control loop wiring:
    • connect one phase live wire to the stop button, and then connect to one end of the contactor coil through the start button.
    • The other end of the coil is connected to the other phase live wire through the normally closed point of the thermal relay and the normally closed point of the pressure switch to form a complete control loop.
  • Parallel joint control setting:
    • use communication lines (such as RS485) to connect the controllers of two air compressors, and set the master-slave mode.
    • Configure the unloading pressure (0.02MPa higher than the target pressure is recommended) and the loading pressure (0.02MPa lower than the target pressure) to ensure stable pressure.

2. Key points of pipeline connection

  • the exhaust pipe is connected to the main pipe from above to avoid backflow of condensed water.
  • Pipe diameter is not less than the air compressor exhaust diameter, install isolation ball valve (check valve is not required).

3. Control system settings

  • set the "target pressure", "unloading pressure" and "loading pressure" parameters to ensure that the three-pressure relationship is: unloading pressure> target pressure> loading pressure, and the differential pressure is recommended to be greater than 0.7BAR.
  • Enable the joint control mode, set the rotation time (such as 60 minutes), and balance the running time of the two devices.

2. series connection (recommended for improving gas quality)

applicable Scenarios: High requirements for gas purity, multi-stage filtration or drying.

1. Electrical wiring steps

  • start sequence control:
    • after the first air compressor is started, the second air compressor is controlled to start through the time delay relay (delay 5-8 seconds).
    • The pressure switch of the second air compressor should be slightly higher than the first to prevent premature shutdown.
  • Control loop interlocking:
    • the pressure switches of the two air compressors are connected in series in the control circuit to ensure that the pressure is stopped at the same time when the pressure exceeds the limit.
  • Communication joint control setting:
    • use the communication line to connect the controller, and set the linkage delay time and rotation time.
    • The loading pressure of the second air compressor should be 0.02MPa lower than that of the first one to ensure seamless switching.

2. Key points of pipeline connection

  • the exhaust pipe of the first air compressor is connected to the air inlet of the second air compressor to form a series path.
  • Install high-efficiency filters and dryers in series pipes to improve gas quality.

3. Control system settings

  • set the target pressure of the first air compressor slightly higher than the second to ensure that the gas is fully treated.
  • Enable the joint control mode and set the joint delay time (default 10 seconds) to avoid frequent start and stop.

3. General Installation Precautions

  1. computer room site selection:
    • avoid high temperature, humid and dusty environment and ensure good ventilation (temperature ≤ 40 ℃).
  2. water cooling system:
    • the water inlet pipe is equipped with a 40-mesh water filter, and the water inlet and outlet pipes are equipped with isolation ball valves and winter drain valves.
    • Control the cooling water pressure (0.3-0.5MPa), temperature difference (≥ 0.15MPa) and temperature (≤ 35 ℃).
  3. Ventilation and heat dissipation:
    • low-power units can be equipped with exhaust fans, and high-power units need to use air duct to draw air (the section is consistent with the vent).
  4. Safety grounding:
    • ensure that the resistance of the ground wire meets the requirements to prevent the risk of electric shock.

4. common problems and solutions

Question reason solution
motor fails to start phase sequence error swap any two-phase fire wire
frequent start and stop of equipment improper pressure switch setting adjust the unloading/loading pressure difference
remote control failure communication mode not enabled check the controller communication parameter setting
gas containing water/impurities lack of filtration/drying unit adding filters and dryers in series piping

through the above steps, you can flexibly choose parallel or series connection according to actual needs to ensure the efficient and safe operation of the two air compressors. If there are further questions, it is recommended to contact the equipment manufacturer to provide technical support for specific models.

More Recommendations

  • 2026-04-10

    Air compressor energy consumption detection

    Air compressor energy consumption detection is a process involving many aspects, including detection methods and energy efficiency indicators. The following is a detailed answer on the energy consumption detection of air compressor: 1. detection method The energy consumption detection of air compressor can be tested by laboratory

    View details
  • 2026-04-09

    Which is better, empty machine without oil or oil type

    Which is better, oil-free or oil-free air compressor-comparative analysis of water-lubricated air compressor and oil-injected air compressor of Shanghai granklin group in the air compressor market, oil-free air compressor and oil-injected air compressor are two common types. They each have advantages

    View details
  • 2026-04-10

    The difference between integrated air compressor and split

    The main differences between the integrated air compressor and the split air compressor are reflected in the structure, energy efficiency, maintenance cost and application scenarios. Structure: The integrated air compressor integrates all components into one body, with compact structure and easy installation. It goes through the tube

    View details
  • 2026-04-10

    What areas are gas compressors used?

    Gas compressors play an important role in many fields. They are widely used in industrial production to provide power or compressed gas for various processes. Whether it is manufacturing, chemical industry, or oil and gas industry, gas compression

    View details
  • 2026-04-15

    How much pressure is generally used for air compressors in the chemical fiber industry

    Technical description of air compressor pressure standard in chemical fiber industry As an important application field of compressed air system, the process characteristics of chemical fiber industry determine the special requirements of air compressor pressure setting. Now combined with industry production practice, on the chemical fiber enterprise air compressor pressure standards and

    View details
  • 2026-04-10

    How long is the new screw machine maintenance?

    The maintenance cycle of the new screw machine can be determined with reference to the following aspects: First, under normal circumstances, the maintenance of the screw machine can be divided into daily maintenance and major maintenance. Daily maintenance is mainly the daily maintenance and cleaning of the equipment, the general recommended cycle is 1-2

    View details
  • 2026-04-10

    What are the contents of the air compressor safety measures

    Air compressor safety measures mainly include the following: installation of exhaust valve: effective control of pressure release, to prevent excessive pressure caused by explosion. Regular inspection and maintenance: to ensure the normal operation of the air compressor, reduce the occurrence of failures and accidents. Check contents

    View details
  • 2026-04-14

    What is the fault of the air compressor working all the time?

    The continuous operation of the air compressor may be caused by a variety of faults. The following are some common causes and corresponding solutions: common faults and causes of leakage in the gas circuit system: when there is leakage in the gas circuit system, such as loose gas pipe joints, lax valve sealing, etc., empty

    View details
  • 2026-04-09

    class ii compressed air storage tank is a special equipment

    Belong. Class II pressure vessels belong to special equipment, and Class II vessels are also called "Class II pressure vessels". Refers to the safety technical supervision and management of pressure vessels, according to the pressure grade of the vessel (see "pressure vessel & rdquo

    View details
  • 2026-04-13

    Air compressor standard

    The standard of air compressor (air compressor) involves many aspects, including design, manufacture, installation, operation and performance evaluation. The following are some of the main air compressor standards and their overview: 1. International Standard ISO 1217: Overview: Air

    View details