2026-04-09Views:
1. Add the following net cover at the air compressor room and air inlet of the air compressor.
2. Regularly purge the air inlet of the air compressor, filter cotton, cooler and cooling fan cover of the motor.
3. Regularly observe the operating temperature of the air compressor. In case of high temperature, check the unit in time. 4. Contact our service provider in time if you have any questions to avoid long-term "sick" work of the machine.
Want screw air compressor
efficient and stable operation, in addition to regular maintenance, daily maintenance and inspection is also very important. Here are five good habits of permanent magnet air compressors in use.
1. Keep the air compressor station clean and tidy.
Dust and debris oil will not only pollute the lubricating oil, increase the wear and corrosion of parts, but also cause machine failure. Keeping the machine room clean can effectively extend the service life of the machine and ensure the normal operation of the machine.
2. Check the air compressor accessories.
Regularly check whether the air compressor accessories are loose and whether the pipe joints are leaking. It should be noted that the use cycle of consumable parts of air compressor accessories should be recorded. After reaching a certain period, it must be cleaned and replaced in time.
3. Air compressor lubricating oil.
Check the oil level of the lubricating oil. Once it is lower than the oil level, it should be added in time. Be careful not to mix different brands of air compressor oil, and add new oil only after discharging clean old oil.
4. Drain water from the air storage tank.
Gas storage tank, cooler and oil-water separator should release oil and water frequently;
5. Check the unit motor.
Always check whether there are sundries in the motor, whether the coil is damaged, whether the stator and rotor are rubbing, to prevent the motor from being burned after starting;
6. Pay attention to the operation status of the unit.
Always pay attention to the instrument, air pressure reading and unit sound when the air compressor is running. Timely troubleshooting of abnormalities. Secondly, the pressure in the gas tank shall not exceed the pressure specified in the nameplate. The unit drain valve shall be opened 1~2 times every 2~4 hours to drain clean condensate. Do a good job of cleaning the machine at the same time pay attention to the long time after the machine running can not be washed with cold water.
The above is the daily use of air compressor need to pay attention to a few points. Standardized use of air compressor can ensure smooth production.
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2