The oil content of the general air compressor will vary according to different types and application scenarios. Here are some specific oil content standards:
for ordinary air compressors, the national standard stipulates that the liquid oil content in the compressed air shall not exceed 5 mg/m & sup3;, and the oil vapor content in the compressed air shall not exceed 0.5 mg/m & sup3;.
The oil content in the outlet air of the micro-oil air compressor shall not be higher than 0.01 mg/m & sup3;. For oil-free air compressors, it is generally believed that the oil content is 0.01ppm.
In some industries with high requirements for compressed air quality, such as food, medicine and electronics, the exhaust oil content standard may be more stringent, usually less than 1 mg/m & sup3; or lower.
In addition, for the screw air compressor, the general oil content is about 3ppm, but in fact, the oil content of the air compressor is below 5ppm, it can be called a high-quality oil-free air compressor.
It should be noted that the high oil content of the air compressor may lead to blockage and corrosion of the gas pipeline, as well as the pollution of industrial products, so the oil content of the air compressor should be strictly controlled. At the same time, the specific oil content standard may vary depending on different countries or regions, different air compressor types and uses.
In general, the oil content standard of the air compressor is not a fixed value, but is determined according to the type of air compressor, application scenario and relevant national or regional standards. Therefore, when selecting and using air compressors, you should refer to relevant standards and specifications to ensure its performance and safety.
The semiconductor industry has very strict requirements for compressed air, because compressed air is directly in contact with the product, and its quality and purity directly affect the quality and performance of the product. The following are the main requirements for compressed air in the semiconductor industry: Particle control: due to semi-conductivity
Whether the import and export gas volume of the air compressor is equal depends on the specific working mode and conditions. In the actual situation, due to factors such as gas leakage and moisture discharge during the compression process, the inlet and outlet gas volume (by mass or mole) of the air compressor is not always equal
The compressed air of the fermentation tank mainly comes from the air compressor. These compressors provide the fermenter with the required compressed air through a specific system. The following is a detailed explanation about the source of compressed air in the fermentation tank: The role of the air compressor: air
Q: air consumption of equipment and air compressor selection? Answer: according to the air consumption of equipment to choose air compressor first consider two points: 1, the pressure problem, need to understand the normal use of all equipment pressure range, take the maximum and minimum, and then according to the maximum increase of 1kg pressure to select the air compressor.
The pressure of the factory gas source is not a fixed value, but is determined according to specific application requirements and equipment specifications. The following are some common air source pressure ranges and considerations: common air pressure range: common air pressure range in factories is usually 0.2 ~
The hospital is a place with very high requirements for air quality. The use of compressed air in the hospital is much more extensive than most people think, and it runs through almost all aspects of diagnosis and treatment, surgery, nursing, and logistics.
The price of screw air compressor repair varies due to a variety of factors, including brand, model, fault type, repair scope, and service provider's pricing strategy. The following is some analysis and summary of the maintenance price of screw air compressor: 1. price range
Screw type air compressor sound is a common problem, which may be caused by a variety of reasons. The following are some possible reasons and corresponding solutions: Cause analysis Air flow pulsation: When the screw air compressor is working, the intake valve and the exhaust valve switch phase
To solve the water problem in the air compressor, we can start from many aspects. The following are some specific solutions and suggestions: 1. check and clean the cooling water pump. Regularly disconnect the power supply of the cooling water pump, open the shell of the cooling water pump, and check whether there is foreign matter in the pump
When the water vapor of the air compressor is more, it can be solved from the following aspects: 1. check and maintain the installation of the drainage system and regularly check the drain valve: install the drain valve at the bottom of the air tank of the air compressor to ensure that the condensate can be smoothly discharged. Periodic inspection
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2