In order to make the oil-free air compressor can run normally and reliably and ensure the service life of the unit, a detailed maintenance plan must be formulated, and the fixed person operation, regular maintenance and regular inspection and maintenance must be carried out to keep the oil-free air compressor clean, oil-free and dirt-free.
Main components shall be maintained according to the following table:
note:
a, according to the above table maintenance and replacement of each component must be determined: the pressure in the oil-free air compressor system has been released, separated from other pressure sources, the switch on the main circuit has been disconnected, and the safety mark of not closing has been made.
B. The replacement time of compressor cooling lubricating oil depends on the use environment, humidity, dust and whether there is acid and alkaline gas in the air. The newly purchased oil-free air compressor shall be replaced with new oil for the first 500 hours of operation, and then replaced every 4000 hours according to the normal oil change cycle. Machines with annual operation less than 4000 hours shall be replaced once a year.
C, the oil filter in the first boot operation 300-500 hours must be replaced, the second time in the use of 2000 hours of replacement, after the normal time every 2000 hours to replace.
D, maintenance and replacement of air filter or intake valve remember to prevent any debris into the compressor host cavity. When operating, the entrance of the host is closed. After the operation is completed, rotate several circles by hand according to the rotation direction of the host to make sure there is no obstacle before starting the machine.
E. Check the tightness of the belt every 2000 hours or so of the machine. If the belt is loose, adjust it until the belt is tight. In order to protect the belt, it is necessary to prevent the belt from being scrapped due to oil pollution during the whole process.
F, each oil change, must be replaced at the same time the oil filter.
G, replace the parts as far as possible the original company parts, otherwise there is a matching problem, the supplier will not be responsible.
Clean the cooler
every time the oil-free air compressor runs for about 2000h, in order to remove dust on the heat dissipation surface, the cooler purge hole cover on the fan bracket shall be opened, and the cooler shall be purged with a dust blowing gun until the dust on the heat dissipation surface is cleaned. If the heat dissipation surface is seriously dirty and difficult to purge, the cooler can be removed, the oil in the cooler can be poured out and the four inlets and outlets can be closed to prevent dirt from entering, then the dust on both sides can be blown off with compressed air or washed with water, and finally the water stains on the surface can be dried. Place back in position.
Remember! Do not use iron brush and other hard objects to scrape dirt, so as not to damage the surface of the radiator.
Drain condensate
the moisture in the air may condense in the oil and gas separation tank, especially in humid weather, when the exhaust temperature is lower than the air pressure dew point or shutdown cooling, there will be more condensed water precipitation. Too much water in the oil will cause emulsification of the lubricating oil and affect the safe operation of the machine, such:
1, resulting in poor lubrication of the compressor host;
2. The oil and gas separation effect becomes worse, and the pressure difference of the oil and gas separator becomes larger;
3, causing corrosion of machine parts.
Therefore, a condensate discharge schedule should be developed based on humidity conditions.
Condensate water discharge method
it should be carried out after the machine is shut down, there is no pressure in the oil and gas separation tank, sufficient cooling, and the condensed water is fully precipitated, such as before starting up in the morning.
① Screw out the front screw plug of the ball valve at the bottom of the oil and gas separation tank.
② slowly open the ball valve drainage, until there is oil flow, close the ball valve.
③ Screw on the front screw plug of the ball valve.
The operating environment of air compressor shall be below 38 ℃. Improve the ventilation system of the air compressor room, and increase the exhaust fan in the air compressor room to discharge the hot air, thereby reducing the temperature. (Note: A heat source with high temperature cannot be placed around the air compressor) If the temperature around the machine is relatively high, the temperature sucked by the machine will be too high, so that the oil temperature and exhaust temperature will also increase accordingly. These are all needs in summer. Attention
Granklin air compressor is the first choice. The air compressor produced by Granklin Group adopts water lubrication, the whole machine is made of stainless steel, and the compressed gas is 100% free of oil. The traditional method of determining the compressed air requirements of a new air compressor is to use the gas volume of all gas-using equipment.
Oil-free, oil-free air water-lubricated screw air compressors are becoming more and more popular in the market, so what are the options for manufacturers of this series of screw air compressors? Shanghai Granklin Group is a professional manufacturer of "screw air compressors", as a brand enterprise. Granklin production of water-lubricated screw air compressor, oil-free air compressor market sales are rising year by year, more and more popular with users.
Screw air compressors are more common in the air compressor market, gradually replacing piston machines. Basically the piston machine has been taken off the market. But how do you know the price of an air compressor? Users who do not understand must bear the burden.
The disadvantage of water lubrication is that the requirements for lubricating water are relatively high. For example, the advantages of pharmaceutical factories to meet the standard of production water are energy saving, low follow-up maintenance cost and less consumables. Only air filter and water filter without oil, as the name implies, are air compressors that do not use oil lubrication to produce
Compressed air is widely used and is the second largest power energy after electricity. Therefore, air compressors, as general equipment, are widely used in various industries. Air occupies a certain space, but it has no fixed shape and volume. In the right
Contemporary screw air compressor not only uses the traditional screw, its structure, technology, but also uses a variety of materials, design and manufacture of a wide range of equipment models, the use of advanced technology developed products, so that a certain amount of screw and other materials can meet the user labor, production
Precautions for dry oil-free air compressor: 1. Safety matters must be observed during use to prevent fire, electric shock, personal injury and other accidents. 2, keep the workplace clean; chaos can easily lead to accidents. 3, pay attention to the workplace environment: air compressor can not let the wind and rain, do not work in damp and dark places, do not work in the storage of flammable and explosive liquid gas and dusty places.
The water-lubricated air compressor produced by Shanghai Granklin Group is oil-free, environmentally friendly and energy-saving. The air compressor machine is made of stainless steel, so the gas compressed by the air compressor is oil-free, and the gas storage tank should also keep up with it? The answer is yes, if we use carbon steel gas storage tanks and non-stainless steel pipes, etc., then the gas will be greatly reduced. Of course, this depends on the application scenario. If stainless steel gas storage tanks and pipes can be fully used, the gas will reach the best when the air compressor is lubricated with water.
View detailsI believe everyone has experienced the air compressor host or motor overload, maybe it is a small problem for you, maybe you are troubled by this fault. The reasons for the failure are: 1. The voltage is too low: the rated working voltage of the general compressor is 380V, and the upper and lower levels are allowed to float at about 5%.