How to deal with the air compressor with water

2026-04-09Views:

The reason why there is water in the air compressor: there is a certain humidity in the air and contains a certain amount of water. when the air is sucked into the compressor for compression, due to the high temperature inside the compressor, the water directly evaporates to form water vapor, which will be discharged from the compressor with the pressure. when we stop the machine, there will be a small amount of water vapor inside the compressor. after the shutdown, the temperature drops, which will form condensed water, these condensed water can not be timely excluded, the formation of stagnant water in the air compressor.

Air compressor air water solution is as follows:

1. There is a drain valve at the bottom of the air compressor cooler. As long as the drain valve is opened immediately, the water inside can be drained clean.

2. You can also install a drain valve at the lowest end of the air compressor storage tank, and you can also drain the water inside.

After the air compressor is exhausted, a cold dryer or dryer can be installed to remove the water. But the use of cold dryer, to check regularly, so as not to affect the drainage effect.