2026-04-10Views:
In summer, when the permanent magnet variable frequency air compressor is used in a continuous high temperature environment, it will accelerate the loss of equipment, and even accelerate the oxidation of the oil in the oil barrel, resulting in cementing. The most common failure is high temperature shutdown. Therefore, it is particularly important to monitor the exhaust temperature of the permanent magnet variable frequency air compressor in time and accurately eliminate the fault caused by the high temperature of the air compressor.
1. Control the ambient temperature of the machine room
the operating environment of the permanent magnet variable frequency air compressor shall be lower than 38 ℃. Improve the ventilation system of the air compressor room, increase the exhaust fan of the permanent magnet variable frequency air compressor room to discharge hot air, thereby reducing the temperature.
If the temperature around the machine is relatively high, it will cause the suction temperature of the machine to be too high, so that the oil temperature and exhaust temperature will rise accordingly, which should be paid attention to in summer.
2. Air-cooled air compressor, clean up radiator dust
the radiator is kept smooth and clean, and the dust is large. The radiator should always clean up the dust, and ensure that the permanent magnet variable frequency air compressor sucks in the smooth first line of air and dust radiator, which will also cause the permanent magnet variable frequency air compressor oil The filter is blocked, causing the lubricating oil path to be blocked, and the amount of oil entering the host is small, resulting in high temperature and cooling.
3, water-cooled air compressor can reduce the inlet water temperature
check whether the cooling water temperature and water pressure are normal. The inlet water temperature of the air compressor is generally not more than 35 ℃, and the water pressure is between 0.3 and 0.5Mpa. At the same time, the scale of the cooler is removed to ensure the heat exchange efficiency. If the water temperature does not meet the requirements, a cooling tower can be installed.
4, Regular maintenance of permanent magnet variable frequency air compressor filter
permanent magnet frequency conversion air compressor filters mainly include: air filter, oil filter, oil and gas separator. The clogging of the air filter will cause the air compressor to be overloaded and overloaded for a long time, causing the temperature to be too high. Clogging of the oil core will cause high internal pressure and high temperature. The clogging of the oil filter will cause the flow to decrease and generate high temperature.
The dust in the air sucked by the permanent magnet variable frequency air compressor is blocked by the air filter. In order to avoid premature wear of the screw compressor and clogging of the fine filter element in the oil and gas separator, it is usually necessary to replace the new filter element after a period of operation. At the same time, check whether the oil filter and filter element of the oil and gas separator need to be replaced.
5. Use genuine air compressor oil during maintenance
insufficient oil supply for the permanent magnet variable frequency air compressor or insufficient oil supply inside the machine will also cause the air compressor temperature to be too high. When the weather is hot in summer, the position of the oil level mirror oil in the oil and gas barrel should be checked. If it is found that the oil level is lower than the oil level mark, the oil level should be stopped after refueling to prevent high temperature. In addition, be sure to use genuine air compressor oil to ensure the operation of the air compressor.
In summer, in order to ensure the smooth operation and smooth production of your permanent magnet variable frequency air compressor, please regularly maintain the permanent magnet variable frequency air compressor equipment.
Buy a well-known water-lubricated air compressor, such as Shanghai Granklin Group, and a good quality oil-free air compressor will not be so easy to break. The oil-free air compressor has the advantages of low noise, high compressed air quality, stable performance, and convenient movement. In order to ensure its
1. Check the dryer: The dryer is a good way to remove moisture from the air, and the dryer is an inseparable part. Like compressors, dryers are affected by changes in temperature and humidity. As the seasons change and the warm days come
View detailsWhy do you need to change the air compressor oil regularly? 1. Mechanical oil is an aromatic hydrocarbon synthesized by chemical industry, and when the air compressor running at high pressure and high temperature is running back and forth, it will continue to decompose small molecules of cyclic hydrocarbons.
Granklin's water-lubricated air compressor is 100% oil-free and suitable for high-end industries such as food and medical treatment. Fully localized, in the service and product quality has been guaranteed.
View detailsIn the application of some special scenes of compressed gas, we need to use explosion-proof ability of "explosion-proof air compressor", but most people only know "explosion-proof air compressor", but do not know what is "explosion-proof air compressor".
Shanghai granklin group water lubricated air compressor factory direct sales, air compressor use: 1, can be used as air power-air after compression can be used as power, mechanical and pneumatic tools, as well as control instruments and automation devices, instrument control and automation devices, such as tool replacement of machining centers, etc.
View detailsThe "water-lubricated air compressor" produced by granklin group emits light and heat in various industries. as an "oil-free air compressor" product, water is used as a lubricating substance. there are many advantages, such as: compressed gas is 100% free of oil, and the overall temperature of the air compressor is lower.
The full name of the air compressor is the air compressor; a machine designed according to the working principle that the rotation of the twin screw (also known as the yin and yang rotor) causes the gas to produce volume changes. It can inhale natural air and then complete the work through several internal processes. The final discharge meets the pressure
shanghai granklin group engaged in water lubrication oil-free screw air compressor production, research and development, sales. Permanent magnet variable frequency air compressor manufacturers, water lubricated air compressor manufacturers, variable frequency air compressor manufacturers, factory price direct national delivery, there are cases.
View detailsShanghai Granklin (Group) Co., Ltd. is located in Shanghai Baoshan District Robot Industrial Park covers an area of 60 acres, is China's large-scale energy-saving oil-free screw machine production base, products are widely used in food, medicine, machinery and electronics, textile and other industries.
View details2018 Granklin Group. All rights reserved 沪ICP备18000439号-2