Common Troubleshooting of Permanent Magnet Variable Frequency Air Compressor in Summer

2026-04-10Views:

In summer, when the permanent magnet variable frequency air compressor is used in a continuous high temperature environment, it will accelerate the loss of equipment, and even accelerate the oxidation of the oil in the oil barrel, resulting in cementing. The most common failure is high temperature shutdown. Therefore, it is particularly important to monitor the exhaust temperature of the permanent magnet variable frequency air compressor in time and accurately eliminate the fault caused by the high temperature of the air compressor.

1. Control the ambient temperature of the machine room

the operating environment of the permanent magnet variable frequency air compressor shall be lower than 38 ℃. Improve the ventilation system of the air compressor room, increase the exhaust fan of the permanent magnet variable frequency air compressor room to discharge hot air, thereby reducing the temperature.

If the temperature around the machine is relatively high, it will cause the suction temperature of the machine to be too high, so that the oil temperature and exhaust temperature will rise accordingly, which should be paid attention to in summer.

2. Air-cooled air compressor, clean up radiator dust

the radiator is kept smooth and clean, and the dust is large. The radiator should always clean up the dust, and ensure that the permanent magnet variable frequency air compressor sucks in the smooth first line of air and dust radiator, which will also cause the permanent magnet variable frequency air compressor oil The filter is blocked, causing the lubricating oil path to be blocked, and the amount of oil entering the host is small, resulting in high temperature and cooling.

3, water-cooled air compressor can reduce the inlet water temperature

check whether the cooling water temperature and water pressure are normal. The inlet water temperature of the air compressor is generally not more than 35 ℃, and the water pressure is between 0.3 and 0.5Mpa. At the same time, the scale of the cooler is removed to ensure the heat exchange efficiency. If the water temperature does not meet the requirements, a cooling tower can be installed.

4, Regular maintenance of permanent magnet variable frequency air compressor filter

permanent magnet frequency conversion air compressor filters mainly include: air filter, oil filter, oil and gas separator. The clogging of the air filter will cause the air compressor to be overloaded and overloaded for a long time, causing the temperature to be too high. Clogging of the oil core will cause high internal pressure and high temperature. The clogging of the oil filter will cause the flow to decrease and generate high temperature.

The dust in the air sucked by the permanent magnet variable frequency air compressor is blocked by the air filter. In order to avoid premature wear of the screw compressor and clogging of the fine filter element in the oil and gas separator, it is usually necessary to replace the new filter element after a period of operation. At the same time, check whether the oil filter and filter element of the oil and gas separator need to be replaced.

5. Use genuine air compressor oil during maintenance

insufficient oil supply for the permanent magnet variable frequency air compressor or insufficient oil supply inside the machine will also cause the air compressor temperature to be too high. When the weather is hot in summer, the position of the oil level mirror oil in the oil and gas barrel should be checked. If it is found that the oil level is lower than the oil level mark, the oil level should be stopped after refueling to prevent high temperature. In addition, be sure to use genuine air compressor oil to ensure the operation of the air compressor.

In summer, in order to ensure the smooth operation and smooth production of your permanent magnet variable frequency air compressor, please regularly maintain the permanent magnet variable frequency air compressor equipment.

More Recommendations

  • 2026-04-10

    How about the energy saving effect of permanent magnet variable frequency air compressor

    Frequency conversion air compressor is made for energy saving. General production includes permanent magnet frequency conversion and ordinary frequency conversion. In the world of variable frequency air compressors, the most energy-saving is the permanent magnet variable frequency air compressor. Energy saving is only relatively speaking, its ultimate goal is to save money

    View details
  • 2026-04-10

    Oil-free Air Compressor Select Water Lubricated Air Compressor

    Completely oil-free gas exists, and the "water-lubricated air compressor" produced by Shanghai Granklin Group is currently popular in the domestic market ". It is fully in line with the conditions of "oil-free lubrication air compressor". The air compressor head is made of stainless steel. When working, the air compressor head is filled with lubricating water. What is it like after the atmosphere is sucked in, and it is compressed and discharged. What kind.

    View details
  • 2026-04-10

    Medical standard for silent and oil-free air compressor

    What is a medical mute oil-free air compressor refers to the kind of air compressor suitable for use under medical environmental and sanitary conditions. It requires precision, stronger reliability, environmental protection and tranquility, fresh and clean compressed air, and the output gas can directly contact the human body. Medical air compressors with a displacement of less than 1m 3/min are mostly micro-screw reciprocating.

    View details
  • 2026-04-10

    5 advantages of oil-free water lubrication air compressor

    It is obvious to all that the oil-free water lubrication air compressor is excellent. As a category of air compressor, the sales volume is increasing year by year. Users who do not understand its advantages can read this article. 1. The compressed gas of the non-oil-water lubricated air compressor is 100% oil-free, the whole structure of the air compressor is more reasonable, and the cost of maintenance consumables is less;

    View details
  • 2026-04-10

    Safety Operation Regulations for Air Compressor

    1. The air compressor operator must be the one who has passed the professional training of the Municipal Bureau of Technical Supervision and obtained the qualification certificate of pressure vessel operation, and is allowed to operate only after mastering the operation steps of the air compressor. 2. Before starting up, check whether all important components outside the compressor are fastened. No.

    View details
  • 2026-04-10

    Water-lubricated oil-free air compressor is used for laser cutting with high efficiency

    Generally, screw type air compressor is used to supply gas for laser cutting machine. The water-lubricated screw air compressor produced by Shanghai Granklin Group has stable air supply and long service time. Laser cutting machine industry, can not be separated from the gas demand, can be said to be perennial gas, so that it will cause the phenomenon of large power consumption. However, in recent years, the air compressor market has emerged, and energy-saving air compressors have solved the troubles for companies that use gas all the year round. Especially the permanent magnet variable frequency air compressor, constant pressure gas production, energy saving.

    View details
  • 2026-04-10

    What is the cause of the pressure of the screw air compressor not being able to hit

    During the operation of the screw air compressor, it is sometimes found that the air compressor has a continuous low pressure. Today, we will take you to understand the cause of low pressure in air compressors and how to solve this problem in future applications. Whether the gas consumption increases. Such

    View details
  • 2026-04-10

    Common maintenance methods of screw air compressor

    If the maintenance of the air compressor is not timely, it will have a great impact on the air compressor. The screw air compressor will have a first guarantee for 500 hours of operation and a maintenance for 2000 hours after operation. Screw air compressor oil is good or bad on the oil injection screw

    View details
  • 2026-04-10

    Is it more energy-efficient to choose Granklin oil-free permanent magnet air compressor?

    Why choose granklin oil-free permanent magnet air compressor? Permanent magnet air compressor, as the name suggests air compressor using permanent magnet motor drive, from the largest energy consumption of the motor to reduce the power consumption of air compressor. What are the advantages of using a permanent magnet motor air compressor? In terms of energy consumption, we all know that permanent magnet motors combined with variable frequency controllers, air compressors can supply

    View details
  • 2026-04-10

    Principle and characteristics of water lubricated oil-free single screw air compressor

    Single screw air compressor is now the air compressor industry leader, its working principle is better than the twin screw air compressor. Shanghai granklin group (water lubricated oil-free single screw air compressor) production plant. Those who need to see the goods and visit can visit our company at any time.

    View details