2026-04-09Views:
Air compressor procurement for any enterprise, is not a small expense, as little as tens of thousands, as many as tens of millions, it is necessary to learn the installation essentials of air compressor.
We spent tens of millions of oil-free air compressor units purchased back, how to install better. Granklin air compressor for you to list a few points:
1. The vibration of the screw machine is relatively small and does not need to be fixed foundation. Only let it flat on the ground, and the ground is hard, the equipment is firmly placed, the machine is difficult to make noise because of vibration.
2. If the screw machine is installed upstairs, anti-vibration treatment must be done to prevent vibration from being transmitted to the downstairs or resonating, which is a safety hazard to the air compressor and the building itself.
3. When piping the main pipeline, the pipeline should be slightly inclined to facilitate the discharge of condensed water in the pipeline. The pressure drop of the piping shall not exceed 5% of the set pressure of the air compressor, so it is better to use a larger pipe diameter for piping, which is more effective.
4. A ball valve should be installed at the end of the main pipe to facilitate the discharge of condensed water. The branch pipeline must be connected from the top of the main pipeline to prevent the condensate in the main pipeline from flowing into the gas-using equipment. The air outlet pipeline of the air compressor should preferably have a one-way valve.
5. Minimize the use of elbows and various valves in the pipeline to reduce pressure loss. The main pipe should not be arbitrarily reduced. If it must be reduced, a reducer should be used. Otherwise, mixed flow will occur at the joint, resulting in large pressure loss and affecting the service life of the pipeline.
The air compressor is best equipped with post-processing equipment, such as air storage tanks, dryers, precision filters, etc.
7. If the instantaneous gas consumption of the air compressor gas system is large, it is recommended to install a gas storage tank as a buffer. This can reduce the number of frequent loading and unloading of the unit, reduce the number of control element action, can ensure the safe and reliable operation of the compressor. In general, a gas tank with a capacity of 20% of the exhaust volume can be selected.
For how to choose the oil-free air compressor suitable for your enterprise, please contact us, sales telephone number: 13918023456 contact person: Mr. Hu.
In scientific experiments and research, stable and reliable air compressor is one of the indispensable equipment. As a leader in the air compressor industry, Shanghai Granklin Group provides a variety of efficient and safe products for the laboratory with its excellent product quality and advanced technology.
When the compressed air consumption is higher than the gas production, it is like the expenses of a large family suddenly exceed the income, which makes people feel a little unprepared. This situation may be caused by several factors, let us explore the mystery of it. First of all, can
When choosing a centrifugal air compressor or a screw air compressor, many factors need to be considered, including exhaust volume, pressure requirements, energy efficiency, maintenance costs, etc. For the dosage of 100m & sup3;, the following is the analysis of two air compressors: Centrifugal air compressor: Advantages: Centrifugal air compressor
The main difference between the micro-oil air compressor and the oil-free air compressor is reflected in the lubrication method and the use environment. Lubrication method: micro oil air compressor, also known as oil mist air compressor, will spray a small amount of tiny lubricating oil vapor in the process of air compression. These
The maximum pressure resistance value of the factory air source pressure gauge varies depending on the application scenario, medium type and industry specifications. The following is a specific analysis: 1. common pressure resistance range compressed air system: general standard: the maximum pressure resistance of the compressed air pressure gauge in the factory is usually
Air compressor displacement refers to the volume of air that the equipment can compress and discharge per unit time, usually expressed in cubic meters per minute (m & sup3;/min) or cubic feet per minute (CFM). This indicator reflects the theoretical air supply capacity of the equipment, I .e. the air compressor per minute
Oil-free air compressor common fault maintenance: 1, oil-free air compressor intermittent work, insufficient gas supply. The reason for this failure is: insufficient voltage. Starting from the buzzing sound, if the current running current is greater than 5: 00 a.m. (ordinary 520 watts and 840 watts without oil or oil
Hospital air compressors play a vital role in the medical field. It is one of the main components of the medical air system and is specifically designed to meet the various needs of the hospital's specific environment. The following is a rigorous description of the hospital air compressor: 1. definition and type of hospital air pressure
In the incineration power plant, the air compressor, as the core auxiliary equipment, mainly undertakes the five major functions of instrument control gas supply, material transportation power, safety guarantee support, equipment drive and maintenance, air treatment and purification. The specific functions are as follows: 1. instrument control gas supply: ensure the system
The slow pumping of air compressor may be caused by a variety of reasons. The following are some common reasons and corresponding solutions: Common reasons Pollutant blockage: Air inlet or filter system accumulates dust, grease and other pollutants: These impurities will restrict the smooth flow of gas, and then
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2