2026-04-09Views:
remove and clean the air filter element every 500 hours of operation of the air compressor. Generally, it is replaced every 2000 hours or a year (whichever comes first), and the poor environment shortens the time. When cleaning or replacing, prevent foreign matter from falling into the intake valve to avoid the main engine from being stuck and burned. For the first time, the air compressor should be maintained for 500 hours at the first time, and then replaced every 2000 hours or one year (whichever comes first). In dusty environment, the replacement time should be shortened.
The oil filter alarm indicates that the oil filter is blocked and should be replaced in time. Oil filter replacement shall be carried out after shutdown and pressure relief. When replacing, use a wrench to unscrew the oil filter counterclockwise. In order to prevent the oil from splashing, the plate should be prepared to catch the outflow of lubricating oil. Air compressor maintenance time is 2000 hours, after every 3000 hours or a year (whichever comes first) replacement, when the LCD screen shows "oil and gas separator blockage", the oil and gas separator must be replaced, such as poor environment its replacement time will be shortened.
Replace the new oil after 500 hours of operation, and replace the lubricating oil every 2000 hours (6000 hours of synthetic oil) or one year (whichever comes first). If the air compressor works in dusty or high temperature environment, the oil change period should be shortened accordingly. The air compressor will run for a few minutes, so that the oil temperature rise, in order to facilitate the discharge. Press the stop button to stop and ensure that there is no air pressure in the oil and gas barrel; disconnect the main circuit and mark it. During the maintenance of the air compressor, the lubricating oil in the system shall be completely drained, including the lubricating oil in the pipeline, cooler, oil filter and oil and gas barrel. Open the filler cap and fill in new oil. Tighten the oil filler cap, start up and run for 5-10 minutes, and observe that the oil level should be between the upper and lower limits of the liquid level gauge.
When choosing a centrifugal air compressor or a screw air compressor, many factors need to be considered, including exhaust volume, pressure requirements, energy efficiency, maintenance costs, etc. For the dosage of 100m & sup3;, the following is the analysis of two air compressors: Centrifugal air compressor: Advantages: Centrifugal air compressor
Air compressor room construction standards mainly include the following aspects: 1. room location and layout room in the general layout of the location should be left room for expansion to meet the needs of future development. The machine room should be far away from the explosive, corrosive, toxic gases and dust
In industrial production, the percentage of moisture content in the air is a crucial parameter, which directly affects the stability of the production process and the quality of the product. The water-lubricated screw air compressor produced by Shanghai Granklin Group is characterized by its excellent dehumidification capacity and pure
During the manufacture and installation of air compressors and air storage tanks, as special equipment, daily management must be carried out in accordance with the relevant national and departmental safety management inspection regulations. In recent years, the air compressor explosion caused by the frequent occurrence of safety accidents, to the safety management
2.5m & sup3;/min What is the air compressor? For the gas demand of 2.5m & sup3;/min, it is necessary to select an air compressor with appropriate capacity to meet this demand. The capacity of the air compressor is usually measured in cubic meters per minute (m & sup3;/min) or cubic feet per
The air compressor room is like a gas "kitchen", its main function is to "cook" the compressed air or gas we need. In this special room, multiple air compressors are neatly arranged, just like opening
Power plants have strict requirements on the oil content of compressed air, usually requiring an oil content of no more than 0.1 mg/m & sup3;(ISO 8573-1 Level 2) or lower, and some key systems even require ≤ 0.01 mg/m & sup3;(Level 1). Specific requirements due to system use and industry standards
Oil-free air compressor is a specially designed air compressor, its main feature is that it does not need to use lubricating oil during operation. This type of air compressor is widely used in areas with high air quality requirements, such as medical, pharmaceutical, food processing, etc. On
Oil-free air compressors also need to be drained. The working principle of the oil-free air compressor is mainly to compress the inhaled air through mechanical parts such as pistons, screws or turbines, and then output it as high-pressure gas. In this process, because the air itself contains
Generally good air compressor air filter can be used for 1500-2000 hours and must be replaced after expiration. However, if your air compressor room environment is dirty, a better air compressor filter element will be replaced in 4 to 6 months. If the air compressor air filter
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2