The air compressor has been working without stopping, which may be caused by a variety of reasons. Here are some possible causes and solutions:
controller failure:
check whether the display panel of the controller is working normally. If there is any abnormality, the controller may need to be replaced.
Sensor problems:
check whether the pressure and temperature sensors are working normally. If the sensor is found to be faulty, replace it with a new one.
Driveline fault:
check whether the belt is severely worn or whether the gear is worn, and replace it with a new belt or gear if necessary.
Power and circuit problems:
check whether the power cord is in good contact and whether the circuit is damaged. If there is any problem, repair or replace it.
Incorrect pressure setting:
adjust the pressure setting of the equipment to the normal working range to ensure that the equipment can automatically stop after reaching the set pressure.
Poor lubrication:
regularly check the condition of the lubricating oil, replace the lubricating oil or lubricating parts, and clean the lubrication system to reduce friction and prevent the machine from being difficult to stop.
Gas outlet flow reduction:
clean the gas filter to ensure it is unobstructed, and check the sealing device, adjust or replace the seal to prevent gas leakage.
Cooling system failure:
check whether the amount of cooling water is sufficient, whether the cooling pipe, tube plate and other components are well matched, and make necessary adjustments.
Pipeline leakage or inlet valve problem:
check whether there is air leakage in the pipeline, repair it in time, and ensure that the intake valve is normally opened and not damaged.
For the above possible reasons, should be one by one investigation and the corresponding maintenance or replacement parts. During inspection and repair, be sure to pay attention to safety to avoid accidents. At the same time, regular maintenance and maintenance of air compressors is also an important measure to prevent such problems. If the above methods cannot solve the problem, it is recommended to contact professional maintenance personnel or equipment manufacturer for further inspection and maintenance.