2026-04-09Views:
The use of air compressor is as follows:
1. in the air compressor before operation, should pay attention to the following questions:
1. Keep the lubricating oil in the oil pool within the scope of the scale. Before the operation of the air compressor, check the amount of oil in the oil injector should not be lower than the scale line value.
2. Check whether the moving parts are flexible, whether the connecting parts are fastened, whether the lubrication system is normal, and whether the motor and electrical control equipment are safe and reliable.
3. Before the operation of the air compressor, check whether the protective device and safety accessories are in good condition and complete.
4. Check whether the exhaust pipe is unblocked.
5. Connect the water source and open each water inlet valve to make the cooling water unblocked.
During the operation of the 2. air compressor, attention should be paid to the turning check after long-term shutdown and before starting, and attention should be paid to whether there are any phenomena such as impact, jamming or abnormal sound. Inlet pump
the 3. machinery must be started under no-load condition, and then gradually make the air compressor into load operation after no-load operation is normal.
When the 4. air compressor is operating, after normal operation, you should always pay attention to various instrument readings and adjust them at any time.
During the operation of the 5. air compressor, the following conditions should also be checked:
1. Whether the temperature of the motor is normal and whether the readings of each meter are within the specified range.
2. Whether the operation sound of each machine part is normal.
3. Whether the suction valve cover is hot and the sound of the valve is normal.
4. Whether various safety protection equipment of air compressor is reliable.
After the 6. air compressor is operated for 2 hours, the oil and water in the oil-water separator, intercooler and after-cooler shall be discharged once, and the oil and water in the air storage barrel shall be discharged once per shift.
When the following situations are found in the operation of the 7. air compressor, it should be stopped immediately to find out the cause and eliminate it.
1. The lubricating oil or cooling water is finally broken.
2, the water temperature suddenly increased or decreased.
3, the exhaust pressure suddenly increased, the safety valve failure.
4, the load suddenly exceeds the normal value.
5. Abnormal mechanical sound.
6, the motor or electrical equipment, such as abnormal.
The above is the introduction of the use of air compressor.
In the field of scientific research and experiment, the choice of air compressor is directly related to the accuracy of experimental data and the stability of experimental environment. For laboratories pursuing high precision and high purity, an air compressor with excellent performance and convenient operation is essential. Shanghai
Granklin water-lubricated oil-free air compressor is very suitable for oxygen supply to provide clean compressed air for oxygen production and pressurization. The traditional piston air compressor oil content is too large, the new water-lubricated air compressor to provide compressed gas oil-free, water-free, the help for the medical system is not small.
Permanent magnet variable frequency air compressor and variable frequency screw air compressor have their own unique features in function and application. Which is better to use needs to be judged according to actual needs and use environment. The following are several comparative dimensions between them: energy efficiency: permanent magnet variable frequency air compressor
In the food industry, in order to ensure the hygiene and safety of the production process, oil-free air compressors are usually the preferred equipment. This is because the oil-free air compressor can avoid oil pollution, ensure that the compressed air is clean and sterile, and meet the requirements of food safety. granklin, shanghai
Requirements for solid particle content of compressed air vary according to application fields and specific scenes. International standard ISO 8573-1 and domestic standard GB/T 13277.4 both provide detailed classification and measurement methods. The following are specific instructions: 1. international standard: ISO 8573-1ISO
Permanent magnet variable frequency screw air compressor is a combination of permanent magnet motor technology and frequency control technology screw air compressor. It uses a permanent magnet motor as the power source, and realizes precise control of the motor speed through frequency conversion technology.
Whether the oil-free air compressor is durable depends on a number of factors, including the quality of the air compressor, the use of the environment, the workload and maintenance. First of all, from the quality point of view, the choice of certified brands and models of oil-free air compressor is to ensure
In the medical field, air compressor units play a vital role, especially in the supply and treatment of medical gases. The water-lubricated screw air compressor produced by Shanghai Granklin Group, with its excellent performance and environmental protection characteristics, has become a medical gas system.
Q: oil free screw air compressor and oil injection screw air compressor which is good? A: air quality comparison is better without oil screw air compressor. If no preconditions are added, the oil injection screw air compressor is of course selected in terms of price and exhaust volume, but why is it now
The oil content of the air output of the oil-injected screw air compressor needs to be evaluated in combination with industry characteristics and process requirements. The oil-injected screw air compressor realizes cooling, sealing and lubrication functions by injecting lubricating oil, so a trace of oil will remain in the compressed air. Its oil content level is affected
2018 Granklin Group. All rights reserved 沪ICP备18000439号-2