Safety Operation Regulations for Air Compressor

2026-04-10Views:

1. check the protective device and safety accessories before starting, and can only start when they are in good condition.

2. check whether the lubricating surface is up to standard.

3. water-cooled air compressor to open the cooling water valve, and then open the motor. When there is no cooling water or the water is stopped, the operation should be stopped.

Open the automatic regulating valve before driving the 4., open the lower valve of the air tank, and turn it by hand

the inertia wheel (big wheel) is allowed to drive after normal conditions for one week. After each part is normal after running for one minute, close the lower valve of the air storage tank.

In case of abnormal sound, smell, vibration or failure of the 5. in operation, it should be stopped immediately and checked before use.

The 6. pressure gauge is calibrated once a year. The external inspection of the gas tank and pipe joint shall be carried out once a year, and the internal inspection and hydraulic strength test shall be carried out once every three years. Detailed records shall be made. The working pressure shall be marked on the gas tank and the date of the next test.

7. safety valve to do a monthly automatic start test and calibration once every six months, and add lead seal.

8. When checking and repairing, attention should be paid to avoid wood chips, iron chips, cloth, etc. falling into the cylinder, gas tank and pipe.

9. parts that have been cleaned with diesel must be operated for 10 minutes without load before they can be put into normal operation.

10. always pay attention to the change of the pressure gauge pointer, it is forbidden to exceed the specified pressure.

Eleven, after the completion of the work will be released from the gas tank, winter should be released cold water.

Twelve, the accident, should keep the scene, and report to the relevant departments.